Veichi 0.4 Kw to 22 Kw VFD AC Drive Variable Frequency Motor Controller for Various Uses

US$75.00 - 350.00 1 Piece (MOQ)
Port:
Shanghai, China
Production Capacity:
600, 000 PCS/Year
Payment Terms:
L/C, T/T

Last Login Date:

Aug 18, 2025

Main Products:

Inverter, AC Drive, VFD, PLC, HMI, Servo System, Servo Motor, Servo Drive, Pump Inverter, Solar Pump Inverter

Find Similar Products

Product Description

Company Info

Basic Info.

Model NO.
AC10
Application
Three Phase Transducer, General Transducer
Output Type
Triple
Principle of Work
Vector Control Transducer
Switch Mode
PWM Control
Main Circuit Type
Voltage
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Simple Type, Textile Special, Constant Torque Universal Type
Brand
Veichi
Trademark
VEICHI
Transport Package
Carton Bx/Wood
Origin
Suzhou, China

Product Description

>>>  AC10 Series Frequency Inverter Overview

AC10 series frequency inverter is a product developed on the latest technology platform of VEICHI. AC10 products are based on the user's market demand for miniaturization, high reliability and high cost performance. As a narrow-body VFD, AC10 has convenient way of installation, small size, low temperature rise, high protection, strong software performance and many other advantages. AC10 development relies on advanced PLM R&D management system to ensure that the hardware, software, structure and test process are three-dimensional, systematic and can be developed during the development process. Traceability, constant scrutiny in every detail ensures strict rigor and scientific spirit (T3 VFDs only support vector control).

>>> AC10 VFD Product Features

  1. Smart and compact, with a narrow book design.
  2. Various installation methods, rail, side, vertical installation.
  3. Temperature resistance, no derating at an ambient temperature of 50ºC.
  4. Hidden line design makes wiring more convenient.
  5. High protection, isolated air duct, taking into account heat dissipation and dust prevention of devices.
  6. Multiple protections, over-current, and over-voltage protection all the time, wave-by-wave current-limiting protection.
  7. Network design, convenient network expansion, direct plug-in direct expansion.
  8. Power performance, undiminished functions, small but versatile.

>>>  Save twice the installation space, book narrow body design, and various installation methods

  1. Install side by side, no need to reserve clearance.
  2. Side installation, flexible change of installation method.
  3. Rail installation is fast and convenient.

>>>  No derating at an ambient temperature of 50ºC

Independent air duct design, fast heat dissipation, the low-temperature rise of the machine, no need to derating in a high-temperature environment.

>>> Structural design high protection

  1. The air duct is isolated, and the heat is introduced into the air duct after the heating device is processed.
  2. Concentrated heat dissipation, electronic sensitive devices are placed in a closed environment to prevent environmental pollution.

>>> Networking design|Hidden line design

  1. The group network is convenient to expand, and it can be directly connected through the network port for expansion. Users only need to make a network cable connection, which is convenient and beautiful.
  2. The machine is designed with a wire trough on the lower side of the wiring terminal, which can guide the control wiring harness to the wiring trough, and ensure the beautiful wiring in the cabinet and stand-alone use.

>>> Overcurrent suppression protection

Through real-time monitoring of the load current during operation, it is automatically limited to not exceed the set overcurrent suppression point, which has prevented the fault trip caused by the current. This function is especially suitable for some loads with large inertia or severe changes.
>>> Overvoltage suppression protection

When the bus voltage reaches or exceeds the bus overvoltage suppression point during the operation of the inverter, the inverter will automatically adjust the operating frequency to suppress the excessive bus voltage, to ensure that the inverter does not cause overvoltage protection due to the excessive bus voltage.

>>> Wave-by-wave current limit

When the output current exceeds the wave-by-wave current limit point, the hardware current limit protection is triggered, which can restrain the rise of current to a certain extent so that the current does not exceed the inverter protection value, and avoid the current alarm and shutdown due to sudden load or abnormal current.

>>> Computer monitoring software

The computer can manage the parameter storage and download of several inverters. The parameter download function can save the parameter setting work when exchanging the inverter. The monitoring software is equipped with various monitoring, parameter settings, motor self-learning, oscilloscope functions, etc. Only need a simple RS485 serial port, you can simply connect to the computer.
 

>>> Industrial Applications for AC10 Series Frequency Inverter

Application: fan and pump, automated production line, carpentry machinery, smart logistics, food packaging line, and other industries and equipment.

>>> Specifications

ProjectSpecification
Power rangeSingle phase 220V 50/60Hz0.75kW - 2.2kW
Three phase 220V 50/60Hz;0.75kW - 2.2kW
Three phase 380V 50/60Hz;0.75kW - 5.5kW
Power inputVoltage and frequencySingle-phase 220V 50/60Hz; Three-phase 380V 50/60Hz; Three-phase 220V 50/60Hz 
Allow fluctuationVoltage imbalance rate: <3%; Frequency: ±5%; Distortion rate meets IEC61800-2 requirements
Closing impulse currentLess than rated current
Power factor≥0.94 (with DC reactor)
Inverter efficiency≥96%
OutputThe output voltageOutput under rated conditions: 3-phase, 0~input voltage, error less than 5%
Output frequency range0~600Hz
Output frequency accuracy±0.5% of maximum frequency value
Overload capacityT3 model: 150% rated current for 1 minute, 180% rated current for 5s, 200% rated current for 0.5s
S2 model: 150% rated current for 20s, 180% rated current for 0.5s
Main control performanceMotor control modeV/F control without PG, vector control without PG
ModulationOptimize space vector PWM modulation
Carrier frequency1.0~16.0kHz
Speed control rangeVector control without PG, rated load 1:100;
Steady-state speed accuracyVector control without PG: ≤2% of rated synchronous speed;
Starting torqueVector control without PG: 150% rated torque at 0.5Hz;
Torque responseVector control without PG: <20ms;          
Frequency accuracyDigital setting: maximum frequency×±0.01%; analog setting: maximum frequency×±0.2%
Frequency resolutionDigital setting: 0.01Hz; Analog setting: maximum frequency×0.05%
Basic product functionTorque controlTorque setting calculation, torque mode speed limit
DC braking capabilityStarting frequency: 0.00~50.00Hz; Braking time: 0.0~60.0s; Braking current: 0.0~150.0% of rated current
Torque boostAutomatic torque increase 0.0%~100.0%; manual torque increase 0.0%~30.0%
V/F curveFour methods: linear torque characteristic curve, self-set V/F curve, reduced torque characteristic curve (1.1~2.0 power), square V/F curve
Acceleration and deceleration curveTwo ways: linear acceleration and deceleration, S curve acceleration and deceleration
Four sets of acceleration and deceleration time, the time unit is 0.01s, the longest is 65000s
Rated output voltageUsing the power supply voltage compensation function, the rated motor voltage is 100%, which can be set in the range of 50 to 100% (the output cannot exceed the input voltage)
Automatic voltage adjustmentWhen the grid voltage fluctuates, it can automatically keep the output voltage constant
Automatic energy saving operationUnder V/F control mode, the output voltage is automatically optimized according to the load to realize energy-saving operation
Automatic current limitAutomatically limit the current during operation to prevent frequent over-current fault trips
Instantaneous power failure processingIn case of instantaneous power failure, uninterrupted operation is realized through bus voltage control
Standard functionPID control, speed tracking and restart after power failure, jump frequency, frequency upper and lower limit control, program operation, multi-speed, RS485, analog output, frequency pulse output, parameter access level setting, common parameter setting, monitoring parameter comparator output , Counting and timing function, swing frequency function
Frequency setting channelKeyboard digital setting, keyboard potentiometer, analog voltage/current terminal AI, communication setting and multi-channel terminal selection, combination of main and auxiliary channels, which can be switched in various ways
Feedback input channelKeyboard potentiometer, voltage/current terminal AI, communication setting, pulse input PUL
Run command channelOperation panel setting, external terminal setting, communication setting
Input command signalStart, stop, forward and reverse rotation, jog, multi-speed, free stop, reset, acceleration and deceleration time selection, frequency setting channel selection, external fault alarm
External output signal1 relay output, 1 collector output, 1 AO output can be selected as 0~10V or 0~20mA or 4~20mA output,
 Overvoltage, undervoltage, current limit, overcurrent, overload, electronic thermal relay, overheating, overvoltage stall, data protection, fast protection, input and output phase loss protection
 Built-in keyboard: single-line 5-digit digital tube displayIt can monitor the status of 1 inverter
External keyboard: dual-line 5-digit digital tube displayIt can monitor the status of 2 inverter
The function code information of the inverter can be uploaded and downloaded to realize fast parameter copy (only external keyboard)
Output frequency, given frequency, output current, input voltage, output voltage, motor speed, PID feedback amount, PID given amount, module temperature, given torque, output torque, etc. all parameters of the monitoring parameter group
Overvoltage, undervoltage, overcurrent, short circuit, phase loss, overload, overheating, overvoltage stall, current limit, data protection damaged, current fault operating status, historical fault
 If the altitude is lower than 1000 meters, derating for use above 1000 meters, derating by 1% for every 100 meters;
No condensation, icing, rain, snow, hail, etc., solar radiation less than 700W/m2, pressure 70~106kPa
from -10ºC to +50ºC, derating can be used above 40ºC, the maximum temperature is 60ºC (no-load operation)
5% ~ 95%RH(No condensation)
When 9~200Hz,5.9m/s2(0.6g)
-30 ~ +60ºC
Wall-mounted
IP20
Forced air cooling


>>>  About VEICHI
 
Send your message to this supplier
Mr. Tony

Post a Sourcing Request Now

People who liked this also liked