Application: | High-performance Transducer, Three Phase Transducer, General Transducer |
---|---|
Output Type: | Triple |
Principle of Work: | Slip Frequency Control Transducer |
Switch Mode: | PWM Control |
Main Circuit Type: | Voltage |
Voltage of Power Supply: | High Voltage Variable-Frequency Drive |
Customization: |
---|
Suppliers with verified business licenses
AP100 air compressor implements remote monitoring of the air compressor on-site application status. GPRS wireless transmission technology, intelligent fault detection, SMS notification. During operation, the magnetic field of the motor can be directly monitored, and early warning can be made to reduce the probability of loss of magnetization of the motor.
Applications: Pneumatic and pneumatic control, air drive and participation in chemical reactions, etc.
>>> Specifications
Project | Specification | ||
Power range | 7,500 W-90,000 W | ||
Power input | Voltage and frequency | Three-phase 380V 50/60Hz | |
Allow fluctuation | Voltage ±15%; Frequency: ±5%; Distortion rate meets IEC61800-2 requirements | ||
Closing impulse current | Less than rated current | ||
Inverter efficiency | ≥96% | ||
Output | The output voltage | Output under rated conditions: 3-phase, 0~input voltage, error less than 5% | |
Output frequency range | 0~400Hz | ||
Output frequency accuracy | ±0.5% of maximum frequency value | ||
Overload capacity | 150% rated current for 60s, 180% rated current for 10s, 200% rated current for 2s | ||
Main control performance | Motor control mode | No PG vector control, V/F control | |
Modulation | Optimize space vector PWM modulation | ||
Carrier frequency | 0.6~15.0kHz, random carrier modulation | ||
Speed control range | Vector control without PG-rated load 1:100 | ||
Steady-state speed accuracy | Vector control without PG: ≤1% rated synchronous speed | ||
Frequency accuracy | Digital setting: maximum frequency×±0.01%; analog setting: maximum frequency×±0.2% | ||
Frequency resolution | Digital setting: 0.01Hz; Analog setting: maximum frequency×0.05% | ||
Torque boost | Automatic torque increase 0.0%~100.0%; Manual torque increase 0.0%~25.0% | ||
Rated output voltage | Using the power supply voltage compensation function, the rated motor voltage is 100%, which can be set in the range of 50 to 100% (the output cannot exceed the input voltage) | ||
Automatic voltage adjustment | When the grid voltage fluctuates, it can automatically keep the output voltage constant at V/F | ||
Automatic energy-saving operation | According to the load condition, the output voltage is automatically optimized to realize the energy-saving operation | ||
Automatic current limit | Automatically limit the current during operation to prevent frequent over-current fault trips | ||
Instantaneous power failure processing | In case of instantaneous power failure, uninterrupted operation is realized through bus voltage control | ||
Input command signal | Motor temperature detection (compatible with PTC, KTY84), oil temperature detection PT100, pressure detection (4-20mA) | ||
External output signal | 3 relay outputs, including loading valve, start-stop switch of oil pump, start-stop of main engine cooling fan | ||
Protective function | Host overcurrent, overload protection, fan overload protection, thermal relay protection, overheat protection; protection against motor demagnetization, etc. | ||
Surroundings | Installation site | Indoor, the altitude is lower than 1000m, no corrosive gas and direct sunlight | |
Temperature and humidity | From -10ºC to +40ºC | ||
20% ~ 95%RH(No condensation) | |||
Vibration | Less than 0.5g below 20Hz | ||
Storage temperature | From -25ºC to +60ºC | ||
Installation method | Wall-mounted, vertical cabinet | ||
Protection level | IP20 | ||
Cooling method | Forced air cooling |
Suppliers with verified business licenses