Application: | High-performance Transducer, Three Phase Transducer, General Transducer |
---|---|
Output Type: | Triple |
Principle of Work: | Vector Control Transducer |
Switch Mode: | PWM Control |
Main Circuit Type: | Voltage |
Voltage of Power Supply: | Low Voltage Variable-Frequency Drive |
Customization: |
---|
Suppliers with verified business licenses
While maintaining excellent performance and functions, AC200 series products have been significantly improved in terms of ease of use, maintainability, environmental protection, installation space, and design standards from the perspective of customer applications.
Applications:Fans and pumps, printing and packaging equipment, textile equipment, air compressors, injection molding machines, machine tools, and other industries and equipment.
Project | Specification | ||
Power range | Single phase 220V 50/60Hz Three-phase 220V 50/60Hz |
0.4kW~220kW | |
Three-phase 380V 50/60Hz | 0.75kW~710kW | ||
Three-phase 660V 50/60Hz | 7.5kW~710kW | ||
Three-phase 1140V 50/60Hz | 37kW~710kW | ||
Power input | Voltage and frequency | Single-phase 220V 50/60Hz Three-phase 380V 50/60Hz; Three-phase 220V 50/60Hz Three-phase 660V 50/60Hz | |
Three phase1140V 50/60Hz | |||
Allow fluctuation | Voltage imbalance rate: <3%; Frequency: ±5%; Distortion rate meets IEC61800-2 requirements | ||
Closing impulse current | Less than rated current | ||
Power factor | ≥0.94 (with DC reactor) | ||
Inverter efficiency | ≥96% | ||
Output | The output voltage | Output under rated conditions: 3-phase, 0~input voltage, error less than 5% | |
Output frequency range | Type G: 0~600Hz | ||
Output frequency accuracy | ±0.5% of maximum frequency value | ||
Overload capacity | Type G: 150% rated current for 1 minute, 180% rated current for 10 seconds, 200% rated current for 0.5 seconds | ||
Main control performance | Motor control mode | V/F control without PG, vector control without PG, V/F control with PG, vector control with PG | |
Modulation | Optimize space vector PWM modulation | ||
Carrier frequency | 0.7~16.0kHz | ||
Speed control range | Vector control without PG, rated load 1:100; vector control with PG, rated load 1:1000 | ||
Steady-state speed accuracy | Vector control without PG: ≤2% of rated synchronous speed; vector control with PG: ≤0.05% of rated synchronous speed | ||
Starting torque | Vector control without PG: 150% rated torque at 0.5Hz; Vector control with PG: 200% rated torque at 0Hz | ||
Torque response | Vector control without PG: <20ms; Vector control with PG: <10ms | ||
Frequency accuracy | Digital setting: maximum frequency×±0.01%; analog setting: maximum frequency×±0.2% | ||
Frequency resolution | Digital setting: 0.01Hz; Analog setting: maximum frequency×0.05% | ||
Basic product function | DC braking capability | Starting frequency: 0.00~50.00Hz; Braking time: 0.0~60.0s; Braking current: 0.0~150.0% of rated current | |
Torque boost | Automatic torque increase 0.0%~100.0%; manual torque increase 0.0%~30.0% | ||
V/F curve | Four methods: linear torque characteristic curve, self-set V/F curve, reduced torque characteristic curve (1.1~2.0 power), square V/F curve | ||
Acceleration and deceleration curve | Two ways: linear acceleration and deceleration, S curve acceleration and deceleration | ||
Four sets of acceleration and deceleration time, the time unit is 0.01s, the longest is 650.00s | |||
Rated output voltage | Using the power supply voltage compensation function, the rated motor voltage is 100%, which can be set in the range of 50 to 100% (the output cannot exceed the input voltage) | ||
Automatic voltage adjustment | When the grid voltage fluctuates, it can automatically keep the output voltage constant | ||
Automatic energy saving operation | Under V/F control mode, the output voltage is automatically optimized according to the load to realize energy-saving operation | ||
Automatic current limit | Automatically limit the current during operation to prevent frequent over-current fault trips | ||
Instantaneous power failure processing | In case of instantaneous power failure, uninterrupted operation is realized through bus voltage control | ||
Standard function | PID control, speed tracking and restart after power failure, jump frequency, frequency upper and lower limit control, program operation, multi-speed, RS485, analog output, frequency pulse output | ||
Frequency setting channel | Keyboard digital setting, keyboard potentiometer, analog voltage terminal VS, analog voltage/current terminal AI, analog current terminal AS, communication setting and multi-channel terminal selection, main and auxiliary channel combination, expansion card, can be switched in various ways | ||
Feedback input channel | Voltage terminal VS, voltage/current terminal AI, current terminal AS, communication setting, pulse input PUL | ||
Run command channel | Operation panel setting, external terminal setting, communication setting, expansion card setting | ||
Input command signal | Start, stop, forward and reverse rotation, jog, multi-speed, free stop, reset, acceleration and deceleration time selection, frequency setting channel selection, external fault alarm | ||
External output signal | 2 relay outputs, 1 collector output, 1 AO output can be selected as 0~10V or 4~20mA output, 1 AO output can be selected as 0~10V or 4~20mA or frequency pulse output output | ||
Protective function | Overvoltage, undervoltage, current limit, overcurrent, overload, electronic thermal relay, overheating, overvoltage stall, data protection, fast protection, input and output phase loss protection | ||
Keyboard display | LED display | Single line 5-digit digital tube display | It can monitor 1 inverter status |
Dual-line 5-digit digital tube display | It can monitor the status of 2 inverters | ||
Parameter copy | The function code information of the inverter can be uploaded and downloaded to realize fast parameter copy | ||
Status monitoring | All parameters of the monitoring parameter group such as output frequency, given frequency, output current, input voltage, output voltage, motor speed, PID feedback quantity, PID given quantity, module temperature, etc. | ||
Error alarm | Overvoltage, undervoltage, overcurrent, short circuit, phase loss, overload, overheating, overvoltage stall, current limit, data protection damaged, current fault operating status, historical fault | ||
Surroundings | Installation site | If the altitude is lower than 1000 meters, derating for use above 1000 meters, derating by 1% for every 100 meters; | |
No condensation, icing, rain, snow, hail, etc., solar radiation less than 700W/m2, pressure 70~106kPa | |||
Temperature and humidity | from -10ºC to +50ºC, derating can be used above 40ºC, the maximum temperature is 60ºC (no-load operation) | ||
5% ~ 95%RH(No condensation) | |||
vibration | When 9~200Hz,5.9m/s2(0.6g) | ||
Storage temperature | -30 ~ +60ºC | ||
Installation method | Wall-mounted, vertical cabinet | ||
Protection level | IP20 | ||
Cooling method | Forced air cooling |