Certification: CE
Protection: IP20
Installation: Hanging
Housing: Plastic
Transport Package: Carton Box/Wood
Trademark: VEICHI
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
VEICHI GS10
Origin
Suzhou, China
Production Capacity
600, 000 PCS/Year

Product Description

>>> Motor protection function

Multiple inverter basic protection functions;Water pump exclusive protection function(water shortage protection,high and low pressure protection,leakage protection,anti-freeze embroidery protection,sensor disconnection protection).

Mini Size VFD, Frequency Inverter, AC Drive Controller for Water Pumps

>>> Perfectly drive a variety of pump motors

Perfectly drive a variety of water pump motors such as asynchronous, permanent magnet synchronous, synchronous reluctance, etc.

Mini Size VFD, Frequency Inverter, AC Drive Controller for Water Pumps

>>> Multiple water supply functions

Mini Size VFD, Frequency Inverter, AC Drive Controller for Water Pumps

>>> Multiple pump control

1. The pressure of the pipe network is detected by the host and sent to the auxiliary machine. When the pressure is not enough, the auxiliary machine starts and runs according to the set frequency.and the main machine performs constant pressure PID adjustment.
2. The main and auxiliary machines altermately run in sequence at regular intervals to realize the uniform use of the water pump and extend the life of the water pump.


Mini Size VFD, Frequency Inverter, AC Drive Controller for Water Pumps

>>> Network Port Extension Interface

The network model supports RS485(standard), which could be directly extended through the network port. Customers only need to make a network cable connection, convenient and beautiful.

Mini Size VFD, Frequency Inverter, AC Drive Controller for Water Pumps

>>> Installation Methods

Support penetration installation (wall installation,embedded installation):Adapt to various installation environments.

Mini Size VFD, Frequency Inverter, AC Drive Controller for Water Pumps

>>> Protective Design

  1. High protection: completely independent air duct, scientific layout inside the machine, help the heat dissipation of high-power devices and the dust-proof of the sensing device.
  2. High temperature resistance: scientific air duct design, which can quickly dissipate heat, low temperature rise of the machine, and no need of derating at an ambient temperature of 50ºC.
Mini Size VFD, Frequency Inverter, AC Drive Controller for Water Pumps

>>> Industrial Applications for GS10 Mini Pump Drive

Applications: Farmland irrigation, residential water, landscape fountains, swimming pool water supply, desert management.

>>> Specifications

Project Specification
Power Input Voltage, Frequency Single-phase 220V   50/60Hz    Three-phase 220V   50/60Hz     Three-phase 380V   50/60Hz     
Allow fluctuations Voltage imbalance rate: <3%; Frequency: ±5%
The distortion rate meets the requirements of IEC61800-2
Closing impulse current Less than rated current
Power factor ≥0.94 (with DC reactor)
Inverter efficiency ≥96%
Output Output voltage Output under rated conditions: 3 phases, 0 to input voltage, error less than 5%
Output frequency range 0-600.00Hz
Output frequency accuracy ±0.5% of the maximum frequency value
Overload capability T3 model: 150% rated current for 1 minute, 180% rated current for 5 seconds, 200% rated current for 0.5 second
S2 model: 150% rated current 20 seconds, 180% rated current 0.5 seconds
Main control perform-ance Motor type PMSM, AM
Motor control mode No PG V/F control, no PG vector control
Modulation Optimized space vector PWM modulation
Carrier frequency 1.0~16.0kHz 
Speed control range No PG vector control, rated load 1:100
Starting torque No PG vector control: 150% rated torque at 0.5Hz
Torque response No PG vector control: <20ms
Frequency accuracy Digital setting: Maximum frequency × ± 0.01%; analog setting: Maximum frequency × ± 0.2%
Frequency resolution Digital setting: 0.01Hz; Analog setting: Maximum frequency × 0.05%
Basic product function Torque Control Torque setting calculation, torque mode speed limit
DC braking capability Starting frequency: 0.00~50.00Hz
Braking time: 0.0~60.0s
Braking current: 0.0~150.0% rated current
Torque boost Automatic torque increase 0.0%~100.0%
Manual torque increase 0.0% ~ 30.0%
V/F curve Four modes: linear torque characteristic curve, self-set V/F curve, torque reduction characteristic curve (1.1 to 2.0 power), square V/F curve
Acce. / Dece. curve Two ways: linear acceleration and deceleration, S curve acceleration and deceleration
Four sets of acceleration and deceleration time, the time unit is 0.01s, the longest is 650.00s
Rated output voltage Using the power supply voltage compensation function, the rated voltage of the motor is 100%, which can be set within the range of 50 to 100% (the output cannot exceed the input voltage)
Automatic voltage adjustment Automatically keeps the output voltage constant when the grid voltage fluctuates
Automatic energy saving operation Automatically optimize output voltage according to load under V/F control mode to achieve energy-saving operation
Automatic current limiting Automatically limit current during operation to prevent frequent overcurrent fault trips
Instant power down handling Uninterrupted operation through bus voltage control during instantaneous power loss
Standard function PID control, speed tracking and power-down restart, skip frequency, frequency upper and lower limit control, program operation, multi-step speed, RS485, analog output, frequency pulse output
Frequency setting channel Keyboard digital setting, keyboard potentiometer, analog voltage/current terminal AI, communication setting and multi-channel terminal selection, main and auxiliary channel combination, can be switched in various ways
Feedback input channel Keyboard potentiometer, voltage/current terminal AI, communication reference, pulse input X4/PUL
Run command channel Operation panel reference, external terminal reference, communication reference
Input command signal Start, stop, forward and reverse, jog, multi-speed, free stop, reset, acceleration/deceleration time selection, frequency setting channel selection, external fault alarm
External output signal 1 relay output, 1 collector output, 1 AO output can be selected as 0~10V or 4~20mA or 4~20mA output
Protective function Overvoltage, undervoltage, current limiting, overcurrent, overload, electronic thermal relay, overheating, overvoltage stall, data protection, fast protection, input and output phase loss protection
Keyboard display Parameter copy Single line 5-digit display 1 inverter status quantity display
Double line 5-digit digital tube display 2 inverter status quantity display
Parameter copy Upload and download function code information of the inverter for fast parameter copying
Status monitoring All parameters of the monitoring parameter group such as output frequency, given frequency, output current, input voltage, output voltage, motor speed, PID feedback amount, PID given amount, module temperature, etc.
Error alarm Overvoltage, undervoltage, overcurrent, short circuit, phase loss, overload, overheat, overvoltage stall, current limit, data protection damage, current fault operation, historical fault
surroundings Installation place The altitude is less than 1000 meters, and the derating is more than 1000 meters. The derating is 1% for every 100 meters.
No condensation, icing, rain, snow, sputum, etc., solar radiation is less than 700W/m2, air pressure 70~106kPa
temperature humidity -10 ~ +50°C, derating can be used above 40 °C, the maximum temperature is 60 °C (no-load operation)
5% to 95% RH (no condensation)
Vibration At 9 to 200 Hz, 5.9 m/s2 (0.6 g)
Storage temperature -30~+60ºC
Installation method Wall-mounted, closet
Protection level IP20
cooling method Forced air cooling


>>>  About VEICHI
 
Mini Size VFD, Frequency Inverter, AC Drive Controller for Water PumpsMini Size VFD, Frequency Inverter, AC Drive Controller for Water PumpsMini Size VFD, Frequency Inverter, AC Drive Controller for Water Pumps

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Registered Capital
26.6 Million USD
Plant Area
43191 square meters