Application: | High-performance Transducer, Three Phase Transducer, General Transducer |
---|---|
Output Type: | Triple |
Principle of Work: | V/F Control Transducer |
Switch Mode: | PWM Control |
Main Circuit Type: | Voltage |
Voltage of Power Supply: | High Voltage Variable-Frequency Drive |
Customization: |
---|
Suppliers with verified business licenses
A drive with a docking function specially designed for the transformation of old elevators. Integrating frequency converter, brake module, and status indicator, it is convenient for on-site maintenance of equipment and minimizes the cost of frequency conversion transformation of construction elevator.
Applications:Construction elevator
Project | Specification | |
Power range | 30,000 W-37,000 W | |
Power input | Voltage frequency | Three-phase 380V 50/60Hz Three-phase 220V 50/60Hz |
Allowable fluctuation | Voltage: 320V~440V; Voltage imbalance rate: <3%; Frequency: ±5% The distortion rate meets the requirements of IEC61800-2 | |
Output | The output voltage | Output under rated conditions: 3 phases, 0~input voltage, error less than 5% |
Output frequency range | 0~120Hz | |
Output frequency accuracy | ±0.5% of the maximum frequency value | |
Overload capacity | 150% rated current 60s, 180% rated current 10s, 200% rated current 0.5s | |
Main control performance | Motor control mode | Vector control without PG, vector control with PG, V/F control |
Carrier frequency | 0.6~15.0kHz, random carrier modulation | |
Speed control range | Vector control without PG, rated load 1:100 Vector control with PG, rated load 1:1000 | |
Steady-state speed accuracy | Vector control without PG: ≤1% of rated synchronous speed Vector control with PG: ≤0.02% of rated synchronous speed | |
Starting torque | Vector control without PG: 180% rated torque at 0.5 Hz: Torque Vector control with PG: 200% rated torque at 0 Hz | |
Basic functions of the product | DC braking capability | Starting frequency: 0.00~50.00Hz Braking time: 0.0~60.0s Braking current: 0.0~150.0% of rated current |
Rated output voltage | Using the power supply voltage compensation function, the rated motor voltage is 100%, which can be set in the range of 50-100% (the output cannot exceed the input voltage) | |
Frequency setting channel | Keyboard digital setting, keyboard potentiometer, communication setting, multi-channel terminal selection | |
Run command channel | Operation panel setting, external terminal setting, communication setting | |
External input/output signal | 8 logic inputs, 1 high-speed pulse input, 2 analog inputs, 2 analog outputs, 2 relay outputs, 1 collector output, and 1 RS485 communication interface. | |
Protective function | Overvoltage, undervoltage, current limiting, overcurrent, overload, overheating, overvoltage stall | |
Surroundings | Installation site | Indoor, no more than 1000m above sea level, no corrosive gas and direct sunlight |
Temperature humidity | Minus 10 to plus 40°C, 20% to 95%RH (no condensation) | |
vibration | Less than 0.5g below 20Hz | |
Storage temperature | -25~+60ºC | |
Protection level | IP25 | |
Cooling method | Forced air cooling |
Suppliers with verified business licenses