AC10 series frequency inverter is a product developed on the latest technology platform of VEICHI. AC10 products are based on the user's market demand for miniaturization, high reliability and high cost performance. As a narrow-body VFD, AC10 has convenient way of installation, small size, low temperature rise, high protection, strong software performance and many other advantages. AC10 development relies on advanced PLM R&D management system to ensure that the hardware, software, structure and test process are three-dimensional, systematic and can be developed during the development process. Traceability, constant scrutiny in every detail ensures strict rigor and scientific spirit (T3 VFDs only support vector control).
Independent air duct design, fast heat dissipation, the low-temperature rise of the machine, no need to derating in a high-temperature environment.
>>> Structural design high protection
Through real-time monitoring of the load current during operation, it is automatically limited to not exceed the set overcurrent suppression point, which has prevented the fault trip caused by the current. This function is especially suitable for some loads with large inertia or severe changes.
>>> Overvoltage suppression protection
When the bus voltage reaches or exceeds the bus overvoltage suppression point during the operation of the inverter, the inverter will automatically adjust the operating frequency to suppress the excessive bus voltage, to ensure that the inverter does not cause overvoltage protection due to the excessive bus voltage.
When the output current exceeds the wave-by-wave current limit point, the hardware current limit protection is triggered, which can restrain the rise of current to a certain extent so that the current does not exceed the inverter protection value, and avoid the current alarm and shutdown due to sudden load or abnormal current.
The computer can manage the parameter storage and download of several inverters. The parameter download function can save the parameter setting work when exchanging the inverter. The monitoring software is equipped with various monitoring, parameter settings, motor self-learning, oscilloscope functions, etc. Only need a simple RS485 serial port, you can simply connect to the computer.
Application: fan and pump, automated production line, carpentry machinery, smart logistics, food packaging line, and other industries and equipment.
Project | Specification | ||
Power range | Single phase 220V 50/60Hz | 0.75kW - 2.2kW | |
Three phase 220V 50/60Hz; | 0.75kW - 2.2kW | ||
Three phase 380V 50/60Hz; | 0.75kW - 5.5kW | ||
Power input | Voltage and frequency | Single-phase 220V 50/60Hz; Three-phase 380V 50/60Hz; Three-phase 220V 50/60Hz | |
Allow fluctuation | Voltage imbalance rate: <3%; Frequency: ±5%; Distortion rate meets IEC61800-2 requirements | ||
Closing impulse current | Less than rated current | ||
Power factor | ≥0.94 (with DC reactor) | ||
Inverter efficiency | ≥96% | ||
Output | The output voltage | Output under rated conditions: 3-phase, 0~input voltage, error less than 5% | |
Output frequency range | 0~600Hz | ||
Output frequency accuracy | ±0.5% of maximum frequency value | ||
Overload capacity | T3 model: 150% rated current for 1 minute, 180% rated current for 5s, 200% rated current for 0.5s | ||
S2 model: 150% rated current for 20s, 180% rated current for 0.5s | |||
Main control performance | Motor control mode | V/F control without PG, vector control without PG | |
Modulation | Optimize space vector PWM modulation | ||
Carrier frequency | 1.0~16.0kHz | ||
Speed control range | Vector control without PG, rated load 1:100; | ||
Steady-state speed accuracy | Vector control without PG: ≤2% of rated synchronous speed; | ||
Starting torque | Vector control without PG: 150% rated torque at 0.5Hz; | ||
Torque response | Vector control without PG: <20ms; | ||
Frequency accuracy | Digital setting: maximum frequency×±0.01%; analog setting: maximum frequency×±0.2% | ||
Frequency resolution | Digital setting: 0.01Hz; Analog setting: maximum frequency×0.05% | ||
Basic product function | Torque control | Torque setting calculation, torque mode speed limit | |
DC braking capability | Starting frequency: 0.00~50.00Hz; Braking time: 0.0~60.0s; Braking current: 0.0~150.0% of rated current | ||
Torque boost | Automatic torque increase 0.0%~100.0%; manual torque increase 0.0%~30.0% | ||
V/F curve | Four methods: linear torque characteristic curve, self-set V/F curve, reduced torque characteristic curve (1.1~2.0 power), square V/F curve | ||
Acceleration and deceleration curve | Two ways: linear acceleration and deceleration, S curve acceleration and deceleration | ||
Four sets of acceleration and deceleration time, the time unit is 0.01s, the longest is 65000s | |||
Rated output voltage | Using the power supply voltage compensation function, the rated motor voltage is 100%, which can be set in the range of 50 to 100% (the output cannot exceed the input voltage) | ||
Automatic voltage adjustment | When the grid voltage fluctuates, it can automatically keep the output voltage constant | ||
Automatic energy saving operation | Under V/F control mode, the output voltage is automatically optimized according to the load to realize energy-saving operation | ||
Automatic current limit | Automatically limit the current during operation to prevent frequent over-current fault trips | ||
Instantaneous power failure processing | In case of instantaneous power failure, uninterrupted operation is realized through bus voltage control | ||
Standard function | PID control, speed tracking and restart after power failure, jump frequency, frequency upper and lower limit control, program operation, multi-speed, RS485, analog output, frequency pulse output, parameter access level setting, common parameter setting, monitoring parameter comparator output , Counting and timing function, swing frequency function | ||
Frequency setting channel | Keyboard digital setting, keyboard potentiometer, analog voltage/current terminal AI, communication setting and multi-channel terminal selection, combination of main and auxiliary channels, which can be switched in various ways | ||
Feedback input channel | Keyboard potentiometer, voltage/current terminal AI, communication setting, pulse input PUL | ||
Run command channel | Operation panel setting, external terminal setting, communication setting | ||
Input command signal | Start, stop, forward and reverse rotation, jog, multi-speed, free stop, reset, acceleration and deceleration time selection, frequency setting channel selection, external fault alarm | ||
External output signal | 1 relay output, 1 collector output, 1 AO output can be selected as 0~10V or 0~20mA or 4~20mA output, | ||
Overvoltage, undervoltage, current limit, overcurrent, overload, electronic thermal relay, overheating, overvoltage stall, data protection, fast protection, input and output phase loss protection | |||
Built-in keyboard: single-line 5-digit digital tube display | It can monitor the status of 1 inverter | ||
External keyboard: dual-line 5-digit digital tube display | It can monitor the status of 2 inverter | ||
The function code information of the inverter can be uploaded and downloaded to realize fast parameter copy (only external keyboard) | |||
Output frequency, given frequency, output current, input voltage, output voltage, motor speed, PID feedback amount, PID given amount, module temperature, given torque, output torque, etc. all parameters of the monitoring parameter group | |||
Overvoltage, undervoltage, overcurrent, short circuit, phase loss, overload, overheating, overvoltage stall, current limit, data protection damaged, current fault operating status, historical fault | |||
If the altitude is lower than 1000 meters, derating for use above 1000 meters, derating by 1% for every 100 meters; | |||
No condensation, icing, rain, snow, hail, etc., solar radiation less than 700W/m2, pressure 70~106kPa | |||
from -10ºC to +50ºC, derating can be used above 40ºC, the maximum temperature is 60ºC (no-load operation) | |||
5% ~ 95%RH(No condensation) | |||
When 9~200Hz,5.9m/s2(0.6g) | |||
-30 ~ +60ºC | |||
Wall-mounted | |||
IP20 | |||
Forced air cooling |