Application: | High-performance Transducer, Three Phase Transducer, General Transducer |
---|---|
Output Type: | Triple |
Principle of Work: | Vector Control Transducer |
Switch Mode: | PWM Control |
Main Circuit Type: | Voltage |
Voltage of Power Supply: | Low Voltage Variable-Frequency Drive |
Customization: |
---|
Suppliers with verified business licenses
IN310 integrated all-in-one machine is mainly composed of a variable frequency drive, power-on knob switch, speed control positioner, and liquid crystal display. It is an all-in-one machine with multiple advantages, such as multi-function, smooth start-up, ultra-quiet, small size, easy operation, and energy saving.
IN310 integrated: VFD, LCD, rotary switch, digital potentiometer, and other related devices. No need for manual assembly, wiring, and use.
IN310 can be compatible with driving various motors such as AM and PMSM motors. Achieve system upgrades without using other drivers.
Left traditional cabinet mode, adopt mini integrated design, saving installation space.
The latest noise reduction technology can reduce electromagnetic noise during motor running. Client operation creates a quiet environment for users.
Real-time monitoring, periodic sampling, remote modification real-time location tracking, and intelligent display of location through the Internet of Things (website or mobile APP).
Subvert the traditional appearance design, the appearance is amazing, and let the "aesthetic" products into industry and life.
Applications: Synchronous direct-drive fan motors, asynchronous fan motors, fans, water pumps, transmission, food packaging, and other speed control applications.
>>> Specifications
Project | Specification | ||
Power range | 1,500 W-2,200 W | ||
Power input | Voltage and frequency | Single-phase 220V 50/60Hz Three-phase 380V ~480V 50/60Hz | |
Allow fluctuation | Voltage imbalance rate: <3%; Frequency: ±5%; Distortion rate meets IEC61800-2 requirements | ||
Closing impulse current | Less than rated current | ||
Power factor | ≥0.94(With DC reactor) | ||
Inverter efficiency | ≥96% | ||
Output | The output voltage | Output under rated conditions: 3 phases, 0 ~ input voltage, the error is less than 5% | |
Output frequency range | 0~600Hz | ||
Output frequency accuracy | ±0.5% of maximum frequency value | ||
Overload capacity | Type G: 150% rated current 1min, 180% rated current 10s, 200% rated current 0.5s | ||
Type P: 120% rated current for 1min, 140% rated current for 10s, 150% rated current for 0.5s | |||
Main control performance | Motor type | Three-phase asynchronous motor, permanent magnet synchronous motor (sine wave) | |
Motor control mode | V/F control, open loop vector control, closed loop vector control | ||
Modulation | Optimize space vector PWM modulation | ||
Carrier frequency | 1.0~16.0kHz | ||
Speed control range | Vector control without PG, rated load 1:100; vector control with PG, rated load 1:1000 | ||
Steady-state speed accuracy | Vector control without PG: ≤2% of rated synchronous speed; vector control with PG: ≤0.05% of rated synchronous speed | ||
Starting torque | Vector control without PG: 150% rated torque at 0.5Hz; Vector control with PG: 200% rated torque at 0Hz | ||
Torque response | Vector control without PG: <20ms; Vector control with PG: <10ms | ||
Frequency accuracy | Digital setting: maximum frequency×±0.01% | ||
Frequency resolution | Digital setting: 0.01Hz | ||
Basic product function | Torque control | Torque setting calculation, torque mode speed setting | |
Torque boost | Automatic torque increase 0.0%~100.0%; Manual torque increase 0.0%~30.0% | ||
V/F curve | Four methods: linear torque characteristic curve, self-set V/F curve, reduced torque characteristic curve (1.1~2.0 power), square V/F curve | ||
Acceleration and deceleration curve | Two ways: linear acceleration and deceleration, S curve acceleration and deceleration | ||
Four sets of acceleration and deceleration time, the time unit is 0.01s, the longest is 650.00s | |||
Rated output voltage | Using the power supply voltage compensation function, the rated motor voltage is 100%, which can be set in the range of 50 to 100% (the output cannot exceed the input voltage) | ||
Automatic voltage adjustment | When the grid voltage fluctuates, it can automatically keep the output voltage constant | ||
Automatic energy saving operation | Under V/F control mode, the output voltage is automatically optimized according to the load to realize energy-saving operation | ||
Automatic current limit | Automatically limit the current during operation to prevent frequent over-current fault trips | ||
Instantaneous power failure processing | In case of instantaneous power failure, uninterrupted operation is realized through bus voltage control | ||
Standard function | Speed tracking, restart after power failure, jump frequency, frequency upper and lower limit control, program operation, RS485, parameter access level setting, common parameter setting | ||
Frequency setting channel | Keyboard number setting, keyboard potentiometer, communication setting | ||
Run command channel | Button key setting, communication setting | ||
Protective function | Overvoltage, undervoltage, current limiting, overcurrent, overload, electronic thermal relay, overheating, overvoltage stall, data protection, fast protection, input and output phase loss protection | ||
Keyboard display | LED display | rmp (output speed), A (running current), V (input voltage), running status, whether "output speed" is locked, fault interface, etc. | |
Parameter copy | The function code information of the inverter can be uploaded and downloaded to realize fast parameter copy | ||
Status monitoring | Input voltage, output current, output speed | ||
Error alarm | Overvoltage, undervoltage, overcurrent, short circuit, phase loss, overload, overheating, overvoltage stall, current limit, data protection damaged, current fault operation status, historical fault record | ||
Surroundings | Installation site | If the altitude is lower than 1000 meters, derating for use above 1000 meters, derating by 1% for every 100 meters; | |
No condensation, icing, rain, snow, hail, etc., solar radiation less than 700W/m2, pressure 70~106kPa | |||
Temperature and humidity | From -10ºC to +50ºC, derating can be used above 40ºC, the maximum temperature is 60ºC (no-load operation) | ||
5% ~ 95%RH(No condensation) | |||
Vibration | When 9~200Hz, 5.9m/s2(0.6g) | ||
Storage temperature | From -30ºC to +60ºC | ||
Installation method | Wall-mounted, vertical cabinet | ||
Protection level | IP20 | ||
Cooling method | Forced air cooling |