Application: | Three Phase Transducer, General Transducer |
---|---|
Output Type: | Triple |
Principle of Work: | Vector Control Transducer |
Switch Mode: | PWM Control |
Main Circuit Type: | Voltage |
Voltage of Power Supply: | Low Voltage Variable-Frequency Drive |
Customization: |
---|
Suppliers with verified business licenses
method to achieve high torque, high accuracy, high reliability and wide speed drive. Products built-in PLC, PID adjustment, programmable input and output terminals, RS485 interfaces, analog input and output, and other rich control functions. These functions provide highly integrated solutions for engineering and special industry automation applications.
Application: Food Machinery, Packaging Machinery, Textile Machinery, Automatic assembly line
Items |
Specifications |
|
Power range | Single-phase 220V 50/60Hz | 0.75kW~2.2kW |
Three-phase380V 50/60Hz | 0.75kW~4kW | |
Power |
Voltage/frequency |
Single phase 220V 50/60Hz |
Allowable fluctuations |
voltage: ±15%, frequency: ±5% |
|
Control |
Frequency range |
0-400Hz |
Frequency Accuracy |
±0.5% of max frequency |
|
Frequency setting resolution |
0.01Hz:Operating"up"and"down"keys on keyboard |
|
Voltage/frequency characteristics |
Voltage 50% -100%, the rated voltage adjustable, |
|
Carrier frequency |
1.0-15.0KHz/Random carrier modulation |
|
Torque upgrade |
0--25.0% adjustable/auto torque upgrade/random V/F curve optional |
|
Maximum Capacity |
150% for one minute, 180% for 2s, 200% instant jump. |
|
ACC and DEC time |
0.1-6500s |
|
Rated output voltage |
Take advantage of the power supply voltage compensation function, if motor rated voltage is 100%,the voltage can be set in the 50 -100% scope(the voltage output should not exceed the input voltage ) |
|
AVR adjust |
When the grid voltage fluctuates, changes in the output voltage is very small, remained constant V / F |
|
Automatic energy-saving operation |
According to the load conditions, automatic optimize the V/F curves to implement energy saving operation |
|
Standard functions |
PID control, ACC and DECtime adjustable, ACC and DECmode variable, Carrier frequency adjustment, Torque upgrade, Current limiting, Speed tracking and restart, Frequency hopping, Frequency fluctuation limite control, Program running, Multi-steps speed, Pendulum frequency operation, RS485, Analog output, Pulse output frequency |
|
Brake |
Energy-consuming braking, DC braking |
|
Frequency setting input |
Keyboard number settings, keyboard potentiometers/ external terminal VS: 0 ~ 10V, the external terminal AS : 4-20mA, RS485 and signal composition and terminal options |
|
Signal feedback input |
External terminal VS: 0 ~ 10V external terminal AS: 4-20mA, RS485 |
|
Input order signals |
Start, stop, positive and negative rotating , jog, multi-steps speed, free parking, reset, ACC and DECtime choice, frequency settings channels choice, external malfunctions alarm |
|
External output signal |
Relay output, the collector output, 0-10V output, 4-20mA output, the frequency pulse output |
|
Protection function |
Overvoltage, undervoltage, current limiting, over-current, overload, electric thermal relays, overheat, pressure stall, data protection |
|
Display |
Setting |
Function number/data |
Running |
Output frequency, give frequency, output current, input voltage, output voltage, motor speed, PID feedback, quantitative PID, module temperature, input and output terminal |
|
Fault |
Overvoltage, undervoltage, overcurrent, short circuit, phase missing, overload, heat, pressure stall, current limiting, data protection is damaged, current fault operating conditions, historical fault |
|
Condition |
Installation sites |
Indoor, elevation of not more than 1000 m, no corrosive gases and direct sunlight |
Temperature, humidity |
-10 - +40oC, 20% - 90%RH(No condensation) |
|
Vibration |
Below 20Hz less than 0.5g |
|
Storage Temperature |
-25 - +65oC |
|
Installation mode |
Wall-mounted mode |
|
Protection degree |
IP20 |
|
Cooling Mode |
Forced air-cooling |
Suppliers with verified business licenses